SPECIFICATIONS
Cell | Mono |
Weight | 24.5kg±3% |
Dimensions | 2112±2mmx1052±2mm*35±1 mm |
Cable Cross Section Size 4mm2 (IEC) , 12AWG(UL) | |
No. of cells | 144 (6x24) |
Junction Box | IP68, 3 diodes |
Connector | QC4.10(1000V) QC 4.10-35(1500V) |
Cable Length (Including Connector) | Portrait: 300mm(+)/400mm(-); Landscape: 1200mm(+)/1200mm(-) |
Packaging Configuration 682p^MOTContainer |
ELECTRICAL PARAMETERS AT STC
TYPE | JAM72S20 ■445/MR | JAM72S20 ■450/MR | JAM72S20 ■455/MR | JAM72S20 -460/MR | JAM72S20 -465/MR | JAM72S20 -470/MR |
Rated Maximum Power(Pmax) [W] | 445 | 450 | 455 | 460 | 465 | 470 |
Open Circuit Voltage(Voc) [V] | 49.56 | 49.70 | 49.85 | 50.01 | 50.15 | 50.31 |
Maximum Power Voltage(Vmp) [V] | 41.21 | 41.52 | 41.82 | 42.13 | 42.43 | 42.69 |
Short Circuit Current(lsc) [A] | 11.32 | 11.36 | 11.41 | 11.45 | 11.49 | 11.53 |
Maximum Power Current(lmp) [A] | 10.80 | 10.84 | 10.88 | 10.92 | 10.96 | 11.01 |
Module Efficiency [%] | 20.0 | 20.3 | 20.5 | 20.7 | 20.9 | 21.2 |
Power Tolerance | 0-+5W | |||||
Temperature Coefficient of Isc(ajsc) | +0.044%/°C | |||||
Temperature Coeificient of Vbc(3_Voc) | -0.272%/°C | |||||
Temperature Coefficient of Pmax(v_Pmp) | -0.350%/C |
ELECTRICAL PARAMETERS AT NOCT | OPERATING CONDITIONS | ||||||
TYPE | JAM72S20 -445/MR | JAM72S20 -450/MR | JAM72S20 -455/MR | JAM72S20 JAM72S20 ■460/MR -465/MR | JAM72S20 -470/MR | Maximum System Voltage | 1000V/1500V DC |
Rated Max Power(Pmax) [W] | 336 | 340 | 344 | 348 352 | 355 | Operating Temperature | -40C-+85C |
Open Circuit Voltage(Voc) [V] | 46.65 | 46.90 | 47.15 | 47.38 47.61 | 47.84 | Maximum Series Fuse Rating | 20A |
Max Power Voltage(Vmp) [V] | 38.95 | 39.19 | 39.44 | 39.68 39.90 | 40.10 | Maximum Static Load,Front* Maximum Static Load,Back* | 5400Pa(112 lb/ft2) 2400Pa(50 lb/ft2) |
Short Circuit Current(lsc) [A] | 9.20 | 9.25 | 9.29 | 9.33 9.38 | 9.42 | NOCT | 45±2C |
Max Power Current(lmp) [A] | 8.64 | 8.68 | 8.72 | 8.76 8.81 | 8.86 | Safety Class | Class II |
NOCT | Irradiance 800W/m2, ambient temperature 20°C,wind speed 1m/s, AM1.5G | Fire Performance | UL Type 1 | ||||
*For NexTracker installations .Maximum Static Load, Front is 1800Pa while Maximum Static Load, Back is 1800Pa. |